11/17/2024 3:20 p.m.
http://34.77.62.133/en/products/metal-electrical-distribution-box-ip65-for-wall-mounting-300x200x150mm-DF003/
Metal electrical distribution box IP65 for wall mounting 300x200x150mm
REF: DF003
Specifications
  • Size (height x width x depth): 300 x 200 x 150 mm.
  • Distribution box made of 1.2mm thick steel.
  • Painted in gray RAL 7035.
  • It has a quarter turn closure. A key is supplied.
  • 2mm thick galvanized steel sheet, for mounting electrical components.
play_button Watch video
More info
24.28
You save 17.31
Metal electrical distribution box with IP65 protection for wall mounting 300x200x150mm
PVP
41.59
Price including VAT: 51.16
PVD
36.90
Verzendkosten voor: 76,35 *
IE-D02 DY88
2 years
warranty
14 days
returns
100%
safe

In stock
Available more than 10

More info
Specifications
  • Size (height x width x depth): 300 x 200 x 150 mm.
  • Distribution box made of 1.2mm thick steel.
  • Painted in gray RAL 7035.
  • It has a quarter turn closure. A key is supplied.
  • 2mm thick galvanized steel sheet, for mounting electrical components.

More info

Wall mounted electrical distribution box. Metal wardrobe design with door. IP65 environmental protection, allowing the distribution box to be installed outdoors. Totally empty box, except a mounting plate fixed to the bottom of the cabinet. Excellent quality and very robust.

specs
  • Size (height x width x depth): 300 x 200 x 150 mm.
  • Distribution box made of 1.2mm thick steel.
  • Painted in gray RAL 7035.
  • It has a quarter turn closure. A key is supplied.
  • 2mm thick galvanized steel sheet, for mounting electrical components.
  • 130x50mm perforation for the passage of cables. Cover with rubber gasket is supplied.
  • Rubber gasket on the entire door profile to guarantee watertightness.
  • IP65 environmental protection, against humidity and water.
  • Gross Weight: 3.82 kg
  • Product size (width x depth x height): 20.0 x 15.0 x 30.0 cm
  • Number of packages: 1
  • Packages size: 31.2 x 21.5 x 16.0 cm
  • Master-pack: 1

Videos

play_button Watch video

Technical terms

  • IP65
  • IP Protection
  • Galvanized
IP65
IP65 Although it seems very complicated nomenclature IP standards is only one division in two digits, where each digit indicates that it is being served to meet these regulations. For the first digit would be: 0 No protection 1 element to be used for testing (sphere 50 mm in diameter) should not get to go completely. 2 element to be used for the test (area of ??12.5 mm diameter) should not get to go completely. 3 element to be used for testing (sphere 2.5 mm in diameter) must not come at all. 4 element to be used for the test (sphere of 1 mm in diameter) must not come at all. 5 ingress of dust can not be avoided, but it must not enter an amount that interferes with the proper functioning of equipment. 6 polvo should not come under any circumstances in the case of the second digit: Level Protection Against Expected Results Test Method 0 The water enters the equipment quickly. 1 The equipment is placed in their usual work. Should not enter the water when it is dropped from 200 mm height from the team for 10 minutes (at a rate of 3-5 mm³ per minute) 2, the equipment is put into lugar normal work. You should not enter the water when the leaves fall, for 10 minutes (at a rate of 3-5 mm³ per minute). This test should be performed four times at a rate of one for every 15 ° rotation both vertically and horizontally, starting each time the normal position. 3 The equipment is placed in their usual work. You should not enter the water spray at an angle up to 60 ° right and leftvertically to an average of 10 liters per minute and a pressure of 80-100kN/m for a time not less than 5 minutes. 4 The equipment is placed in their usual work. You should not enter the water thrown from any angle to an average of 10 liters per minute and a pressure of 80-100kN/m for a time not less than 5 minutes. 5 The equipment is placed in their usual work. Should not enter waterthrown jet (from any angle) by means of a nozzle 6.3 mm in diameter, at an average of 12.5 liters per minute and a pressure of 30 kN/m for a time not less than 3 minutes and a no closer than 3 meters. 6 The equipment is placed in their usual work. You should not enter water squirted (from any angle) through a nozzle diameter of 12.5 mm, an average of 100 liters per minute and a pressure of 100 kN/m² for at least three minutes at a distance of not less than 3 meters. 7 The object must endure without any filtration complete immersion in 1 meter for 30 minutes. 8 electrical/electronic equipment must withstand (without filtration) complete and continuous immersion depth and during the time specified by the manufacturer of the product with the agreement ofclient, but provided they are more severe than those specified for the value 7. For IP65 should meet the following standard conditions. Would hold cirscuntancias be dusty and prevent to enter under any cirscuntacia, and bear no powerful jets of water.

Do you have any question about this product?